Below is a chart showing all available option on the SXT controllers. Not every system will have all options. DO NOT change these settings unless instructed by a professional, as incorrect settings can impact system performance and may cause damage to your system or home.
Code
|
Parameter
|
Options
|
Description
|
DF
|
Display Format
|
GAL
|
Gallons, with 12-hour AM/PM format
|
Ltr
|
Liters, with 24-hour format
|
||
VT
|
Valve Type
|
dF1b
|
Downflow single backwash
|
Fltr
|
Filter
|
||
dF2b
|
Downflow double backwash
|
||
UFbd
|
Upflow brine first
|
||
UFtr
|
Uplow filter
|
||
Othr
|
Other
|
||
CT
|
Control Type
|
FI
|
Metered (Flow) Immediate - will regeneration immediately after programmed capacity is reached.
|
Fd
|
Metered (Flow) Delayed - will regeneration at the preset time after programmed capacity is reached.
|
||
Tc
|
Time Clock - will regeneration at the set regeneration time after the set number of days has passed.
|
||
dAY
|
Day of the Week - will begin a regeneration cycle on the set day(s) at the set regeneration time.
|
||
NT
|
Number of Tanks
|
1
|
For systems with only 1 media tank.
|
2
|
For systems with 2 media tanks (dual tank softeners only).
|
||
UT
|
Indicates current tank in service
|
U1
|
Tank 1 is in service
|
U2
|
Tank 2 is in service (dual tank softeners only).
|
||
C
|
Capacity
|
1-999.9
(x1000)
|
System capacity, in grains
|
H
|
Hardness
|
1-199
|
Hardness of the water, in grains.
|
RS
|
Reserve Selection
|
SF
|
Percentage saftey factor - a percentage of total capacity
|
rc
|
Fixed reserve capacity - a set number of gallons
|
||
SF
|
Saftey Factor
|
0-50%
|
Sets saftey factor if RS is set to SF
|
RC
|
Reserve Capacity
|
1-(half of calculated capacity)
|
Sets the number of gallons to use as a reserve on systems with RS set to rc
|
DO
|
Day Override
|
OFF-99
|
Initiates the regeneration at the set number of days, regardless of usage.
|
RT
|
Regen Time
|
12:00
|
This sets the time that the regeneration cycle will start.
|
BW
|
Backwash
|
0-199
|
This sets the length of the backwash portion of the cycle.
|
BD
|
Brine Draw
|
0-199
|
This sets the length of the brine draw portion of the cycle.
|
RR
|
Rapid Rinse
|
0-199
|
This sets the length of the rapid rinse cycle.
|
BF
|
Brine Fill
|
0-199
|
This sets the length of the brine fill portion of the cycle.
|
|
|||
D1-D7
|
Day of the Week Setting
|
ON/OFF
|
Controls which days to backwash on Day of Week setups.
|
CD
|
Current Day
|
1-7
|
Used to set the current dayon Day of Week setups.
|
FM
|
Flow Meter Type
|
P0.7
|
3/4" Paddle Wheel Meter
|
Gen
|
Generic or Other Meter
|
||
P2.0
|
2" Paddle Wheel Meter
|
||
t1.5
|
1.5" Turbine Meter
|
||
P1.5
|
1.5" Paddle Wheel Meter
|
||
t1.2
|
1.2" Turbine Meter
|
||
t1.0
|
1" Turbine Meter
|
||
P1.0
|
1" Paddle Wheel Meter
|
||
t0.7
|
3/4" Turbine Meter
|
||
K
|
Meter Pulse Setting
|
0.1-999.9
|
Pulses per gallon, for Gen flow meter setting.
|