Fleck SXT Controller Master Programming Settings

Master Programming Guide for Fleck SXT Controllers

SXT Master Programming Chart

Below is a chart showing all available option on the SXT controllers. Not every system will have all options. DO NOT change these settings unless instructed by a professional, as incorrect settings can impact system performance and may cause damage to your system or home.

Code

Parameter

Options

Description

DF

Display Format

GAL

Gallons, with 12-hour AM/PM format

Ltr

Liters, with 24-hour format

VT

Valve Type

dF1b

Downflow single backwash

Fltr

Filter

dF2b

Downflow double backwash

UFbd

Upflow brine first

UFtr

Uplow filter

Othr

Other

CT

Control Type

FI

Metered (Flow) Immediate - will regeneration immediately after programmed capacity is reached.

Fd

Metered (Flow) Delayed - will regeneration at the preset time after programmed capacity is reached.

Tc

Time Clock - will regeneration at the set regeneration time after the set number of days has passed.

dAY

Day of the Week - will begin a regeneration cycle on the set day(s) at the set regeneration time.

NT

Number of Tanks

1

For systems with only 1 media tank.

2

For systems with 2 media tanks (dual tank softeners only).

UT

Indicates current tank in service

U1

Tank 1 is in service

U2

Tank 2 is in service (dual tank softeners only).

C

Capacity

1-999.9

(x1000)

System capacity, in grains

H

Hardness

1-199

Hardness of the water, in grains.

RS

Reserve Selection

SF

Percentage saftey factor - a percentage of total capacity

rc

Fixed reserve capacity - a set number of gallons

SF

Saftey Factor

0-50%

Sets saftey factor if RS is set to SF

RC

Reserve Capacity

1-(half of calculated capacity)

Sets the number of gallons to use as a reserve on systems with RS set to rc

DO

Day Override

OFF-99

Initiates the regeneration at the set number of days, regardless of usage.

RT

Regen Time

12:00

This sets the time that the regeneration cycle will start.

BW

Backwash

0-199

This sets the length of the backwash portion of the cycle.

BD

Brine Draw

0-199

This sets the length of the brine draw portion of the cycle.

RR

Rapid Rinse

0-199

This sets the length of the rapid rinse cycle.

BF

Brine Fill

0-199

This sets the length of the brine fill portion of the cycle.

 

D1-D7

Day of the Week Setting

ON/OFF

Controls which days to backwash on Day of Week setups.

CD

Current Day

1-7

Used to set the current dayon Day of Week setups.

FM

Flow Meter Type

P0.7

3/4" Paddle Wheel Meter

Gen

Generic or Other Meter

P2.0

2" Paddle Wheel Meter

t1.5

1.5" Turbine Meter

P1.5

1.5" Paddle Wheel Meter

t1.2

1.2" Turbine Meter

t1.0

1" Turbine Meter

P1.0

1" Paddle Wheel Meter

t0.7

3/4" Turbine Meter

K

Meter Pulse Setting

0.1-999.9

Pulses per gallon, for Gen flow meter setting.