Basic Softener Programming of SXT Controllers

Basic Softener Programming of SXT Controllers

Quick Start Guide (USER Programming)
USER programming settings will be dependent on YOUR situation. Use the guide below to program the correct settings.
There is not an average or generalized setting that can be used for hardness. You will need to test your water to find out YOUR hardness. Hardness maps are generalizations for the area and your actual hardness may be much higher or lower than indicated.

Most systems will use default settings and there is very little that needs changed. The USER programming has the most commonly changed settings, and you can go through the settings below to get up and running quickly. To get the most efficient results, make sure to go through the MASTER programming below and set your capacity and brine fill settings.

USER Programming Settings
Press both the UP and DOWN buttons at the same time and hold for 5-10 seconds until the Parameter Display shows DO. Press the Extra Cycle button to advance to each setting shown below, and adjust with the UP/DOWN buttons if necessary.
Continue pressing the Extra Cycle button until you get back to the time of day to save your settings, or press nothing for 5 minutes to discard any changes.
SettingParameterValueDescription
Day OverrideDO3-14Sets regeneration frequency. Only used if water usage does not initiate it first. If you have iron, set no higher than 7, otherwise set no higher than 14. If you have a lot of iron or very dirty water, set lower.
Regen TimeRT2:00Typically set to midnight or 2am to ensure water is not being used. If you have multiple systems, ensure they are set at different times. Typical regeneration process takes roughly 1.5-2 hours
HardnessH1-199Hardness in grains per gallon (GPG). Divide hardness in ppm or mg/L by 17.1 to get GPG. If you have iron or manganese, add 4 for each ppm.
Reserve CapacityRCvariesTake the average number of people in the home and multiply by 75. Use the result here.
Setting the Time

The display will show the time as currently programmed in the system. It can be adjusted by simply pressing the UP or DOWN button repeatedly, holding down a button will cause time to change quickly. You can press the Extra Cycle button to confirm the setting, or just leave it alone for a few seconds and it will save.

MASTER Programming

You WILL need to adjust your capacity setting.The MASTER programming section contains ALL of the available settings, including the settings shown in USER programming. These settings (with the exception of the Capacity and Brine Fill settings) typically use the default values and should not need adjusted.

DO NOT change any settings unless indicated here or directed to do so by an AFWFilters support technician. Other videos and instructions are not designed for AFWFilters systems and may lead to improper operation. If you change a setting in the MASTER programming that is not shown below use the system reset section to reset the system to defaults and adjust ONLY the settings shown below and in the USER programming section.
MASTER Programming Settings
To enter master programming, use the UP or DOWN button to set the time of day to 12:01 PM and press the Extra Cycle button to confirm the time setting. Then press BOTH the UP and DOWN buttons at the same time and hold for 5-10 seconds until the Parameter Display shows DF. Adjust each setting with the UP/DOWN buttons if necessary, then press the Extra Cycle button to advance to the next setting.
The time MUST be set to 12:01PM (PM indicator shown). If you do not get the DF parameter, it is possible the time changed or was not set correctly. Press the extra cycle button to get back to the time of day and try again.
Continue pressing the Extra Cycle button until you get back to the time of day to save your settings, or press nothing for 5 minutes to discard any changes.
The settings shown are the only ones that MAY need adjusted. If a setting is not listed in this chart, DO NOT CHANGE IT.
SettingParameterValueDescription
Valve TypeVTdF1bConfigures the system as a standard downflow system with regeneration (salt) feed.
Control TypeCTFdInitiates the regeneration cycle based on water use.
CapacityCVariesRefer to Brine Fill/Capacity Settings chart below.
Reserve SelectionRSRCUses reserve capacity based on gallons.
Brine FillBFVariesRefer to Brine Fill/Capacity Settings chart below.
The FAQ section contains a complete listing of each setting in the MASTER programming, along with more detailed information about each setting and common issues that may arise from incorrect settings. 
Brine Fill/Capacity Settings
Max efficiency settings will use less salt but regenerate more often.
Max capacity settings will regenerate less often but use more salt. 
Max Capacity
(Cubic feet of resin)
32k
(1.0cf)
40k
(1.25cf)
48k
(1.5cf)
64k
(2.0cf)
80k
(2.5cf)
96k
(3.0cf)
SettingParameterMax Efficiency Value (recommended)
CapacityC212632
425263
Brine FillBF45681012
SettingParameterMax Capacity Value
CapacityC324048648096
Brine FillBF111416222733
These settings are based on a 0.5 GPM brine line flow control (BLFC) used on most systems. If your system uses a different BLFC please refer to the FAQ section for instructions on how to calculate correct settings. 
Resetting your system

If you change a setting not listed in the programming section you can use a reset to return everything to its default value. If your controller is showing odd behavior such as erratic display, no display, or showing an error code, a reset can often correct the problem. Start with the soft reset, and if that does not solve the problem move on to the master reset. If the problem persists contact one of our technicians.

SXT Resets
ResetDirectionsEffect
Soft ResetHold Extra Cycle and Down buttons for 25 secondsThis will reset all settings to default values, but leaves the volume remaining intact.
Hard ResetHold Extra Cycle button while plugging the unit inThis will reset everything in the system. This should only be used if a soft reset does not work.